Subpart 1. Internal combustion engine powered industrial trucks.
The employer shall monitor environmental exposure of employees to carbon monoxide
whenever internal combustion engine powered industrial trucks as defined in Code of
Federal Regulations, title 29, section 1910.178(a)(1), are operated indoors to ensure
that carbon monoxide levels do not exceed those given in Code of Federal Regula- tions,
title 29, section 1910.1000, Table Z-1-A. The air monitoring shall be done at least
quarterly and represent exposures during a day of highest usage in the areas
where employee carbon monoxide exposure is most likely.
Subpart 2. Tailpipe exhaust gas analysis.
The employer shall ensure that powered industrial truck engine exhaust gases do not contain more than one percent carbon monoxide for propane fueled trucks or two percent carbon monoxide for gasoline fueled trucks measured at idle and at three-fourths throttle during final engine tuning in a regular maintenance program.